Skip to main content

Cummins Generators in South Africa

AGP Generators supplies complete generator sets powered by Cummins diesel engines. We are a set supplier — not an official Cummins distributor.

Cummins-powered generator sets are specified where buyers want a globally recognised industrial diesel with strong documentation and a clear parts hierarchy. AGP Generators supplies AGP packaged sets built on Cummins engines for standby and prime duty, typically from mid-range commercial sizes upward. A representative 150 kVA three-phase silent set lists around R289,000 excluding VAT. Fuel burn at 75% load on that class is roughly 28–32 L/h depending on the exact engine map and ambient conditions.

Why Cummins

What buyers and technicians typically weigh when specifying Cummins-powered AGP sets — without manufacturer marketing claims.

Global industrial pedigree

Cummins engines appear in power generation, mining trucks and marine plant worldwide. That pedigree reassures procurement teams writing long-life capital budgets.

Documented parts trees

Clear part numbering and service literature help workshops order the right kit first time — valuable when a data hall or hospital cannot wait on a wrong filter.

Stable governing under step load

Genset-calibrated Cummins platforms handle motor starts and UPS input steps cleanly when the alternator and AVR are matched correctly to the load profile.

Technician recognition

Many industrial diesel fitters in South Africa have Cummins hours on their tickets, which shortens fault-finding on remote or multi-shift sites.

Cummins-powered range

13 AGP units currently listed with Cummins engines.

Model comparison

AGP catalogue units with Cummins engines. Expand the range via quote for non-stock kVA.

ModelEnginePrimeStandbyPhaseFuel @75%NoiseWeightPrice excl. VAT
50 kVA Three Phase Silent Diesel GeneratorCummins 4BTA3.9-G250 kVA55 kVAThree8.6 L/h70 dB800 kgR155 000
66 kVA Three Phase Silent Diesel GeneratorCummins 4BTAA3.9-G266 kVA73 kVAThree11.3 L/h72 dB975 kgR179 300
100 kVA Three Phase Silent Diesel GeneratorCummins 6BTA5.9-G2100 kVA110 kVAThree17.1 L/h72 dB1350 kgR211 000
132 kVA Three Phase Silent Diesel GeneratorCummins 6BTAA5.9-G2132 kVA145 kVAThree22.6 L/h74 dB1700 kgR270 900
150 kVA Three Phase Silent Diesel GeneratorCummins 6CTA8.3-G2150 kVA165 kVAThree25.7 L/h74 dB1900 kgR289 000
300 kVA Three Phase Silent Diesel GeneratorCummins NTA855-G1B300 kVA330 kVAThree51.3 L/h76 dB3550 kgR510 000
450 kVA Three Phase Silent Diesel GeneratorCummins QSX15-G8450 kVA495 kVAThree77 L/h78 dB5200 kgR761 600
750 kVA Three Phase Silent Diesel GeneratorCummins KTA38-G5750 kVA825 kVAThree128.3 L/h80 dB8500 kgR1 250 300
250 kVA Three Phase Prime Power Silent Diesel GeneratorCummins NTA855-G4250 kVA275 kVAThree42.8 L/h76 dB3000 kgR445 000
45 kVA Three Phase Silent Diesel GeneratorCummins 4B3.9-G245 kVA50 kVAThree7.7 L/h70 dB745 kgR144 900
110 kVA Three Phase Silent Diesel GeneratorCummins 6BT5.9-G2110 kVA121 kVAThree18.8 L/h74 dB1460 kgR241 000
220 kVA Three Phase Silent Diesel GeneratorCummins 6CTAA8.3-G2220 kVA242 kVAThree37.6 L/h76 dB2670 kgR402 200
500 kVA Three Phase Containerised Diesel GeneratorCummins KTA19-G4500 kVA550 kVAThree85.5 L/h78 dB5750 kgR1 145 000

Cummins engine models

Common genset engine families and the AGP kVA bands they typically serve. Always confirm the exact engine model on the nameplate of the set you purchase.

Engine modelCylindersDisplacementTypical kVA band
4B3.9-G43.9 L40–60 kVA
6BT5.9-G265.9 L100–150 kVA
6CTA8.3-G268.3 L180–250 kVA
QSL9-G568.9 L250–350 kVA
QSX15-G8615 L400–550 kVA
KTA19-G4619 L500–700 kVA

Parts and service for Cummins-powered sets

We maintain consumable kits for the Cummins-powered AGP models we ship and coordinate major component supply through industrial diesel networks. Installation, ATS integration and CoC handover follow SANS 10142-1 when AGP installs. AGP is not an authorised Cummins distributor; engine names identify the prime mover inside the generator set only.

  • Scheduled oil analysis and hour-based service plans
  • Radiator and charge-air cooler cleaning for dusty sites
  • Load acceptance tests after major services
  • 24/7 breakdown desk for contracted customers

Cummins generator FAQs

No. We package and supply generator sets that use Cummins engines. Official engine distribution and warranty on the bare engine follow the engine maker’s channels; AGP warrants the complete set as supplied.

An AGP 150 kVA three-phase silent set with a Cummins 6BT-class engine lists near R289,000 excluding VAT. Final quotation depends on canopy, alternator brand, fuel tank and controller options.

Yes when sized for UPS input current, redundancy topology and exhaust/noise constraints. Many facilities pair N+1 Cummins-powered frames with closed-transition ATS and regular load-bank proving.

A well-built silent canopy at 150 kVA typically measures around 70–75 dB(A) at 7 m. Site walls, exhaust routing and residential neighbours may still require extra attenuation.

Often yes. Send the engine model, serial and kVA nameplate. We can propose an AGP set on a comparable platform or a drop-in replacement package where dimensions allow.

Tell us your load. We will size it, spec it and price it.

Share your site, duty cycle and critical loads — our engineers return a clear kVA recommendation, bill of materials and fixed quote.

Chat to a power specialist