Skip to main content
320 kVA

320 kVA Three Phase Silent Diesel Generator

320 kVAThree PhaseDiesel2206A-E13TAG3

A 320 kVA three-phase silent diesel generator on a Perkins 2206A-E13TAG3. Fills the gap between 300 and 400 kVA for large commercial and industrial sites. Deep Sea DSE6120 controller, Stamford alternator and a 600 litre bunded base tank.

Explore related ranges: silent diesel generators and Perkins generators.

R 543 700

Excl. VAT

Lead time 6 weeks

Ask about this unit on WhatsApp
  • Nationwide delivery, offloaded and positioned
  • SANS 10142-1 compliant installation available
  • Certificate of Compliance issued on handover
  • 24-month warranty · genuine parts held in stock

Full specification

All values are rendered as crawlable text, never hidden inside tabs.

Ratings

Prime power320 kVA
Standby power352 kVA
Output256 kW
PhaseThree Phase
Voltage230/400 V
Frequency50 Hz
Power factor0.8

Engine

BrandPerkins
Model2206A-E13TAG3
Cylinders6
Displacement6-cyl
AspirationTurbocharged aftercooled
CoolingRadiator and fan
Rated speed1500 rpm

Alternator

BrandStamford
Voltage regulation± 1%
Insulation classH
ProtectionIP23

Control panel

ControllerDeep Sea DSE6120
AMF / ATSIncluded
Transfer time10–15 s
Remote monitoringOptional

Fuel & running

Tank capacity600 L (bunded)
At 50% load37.2 L/h
At 75% load54.7 L/h
At 100% load70 L/h
Runtime at 75%≈ 11 hours

Physical & compliance

Dimensions4600 × 1700 × 2250 mm
Dry weight3770 kg
Noise level76 dB at 7 m
CanopySilent, weather-resistant, lockable
Warranty24 months

What this generator will run

Indicative loads at 320 kVA / 256 kW.

  • Lighting & small power circuits26 kW
  • Commercial refrigeration & cold room58 kW
  • HVAC — packaged units70 kW
  • Three-phase motors (largest 15 kW)48 kW
  • Passenger lift35 kW
  • IT, servers & comms19 kW

Running costs at a glance

Adjust the diesel price to match your area.

R
Consumption at 75% load
54.7 L/h
Cost per hour
R 1 285,45
Cost per 8-hour day
R 10 283,60
Cost per month at 4 h/day
R 113 119,60

Indicative only. Actual consumption varies with load profile, altitude and ambient temperature. Reference full-day cost at 8 h: R 10 283,60; continuous shift month ≈ R 226 239,20.

Frequently asked questions

Answers are plain text on the page for search engines and buyers alike.

What will a 320 kVA generator actually run?

At about 256 kW of prime power, this unit covers mixed commercial loads — lighting, HVAC packages, refrigeration, lifts and IT — provided the largest motor starts are within the set’s surge capacity. We size final selections against your measured or estimated load profile.

Is installation included with the 320 kVA Three Phase Silent Diesel Generator?

Supply can be unit-only or turnkey. SANS 10142-1 compliant installation, AMF integration and a Certificate of Compliance on handover are available nationwide. Ask for a site-specific quote.

How noisy is the silent canopy?

This set is rated at approximately 76 dB(A) at 7 m under standard test conditions. Site layout, barriers and load profile affect the figure you hear on the ground.

What warranty and parts support do I get?

Standard cover is 24 months. Genuine Perkins and alternator parts are held for common service intervals, with regional breakdown response across Southern Africa.

Can I finance or lease this generator?

Yes. We work with asset-finance partners on outright purchase, lease and rent-to-own structures for qualifying businesses. Procurement and tender packs are available on request.

More from the range

View full range

Tell us your load. We will size it, spec it and price it.

Share your site, duty cycle and critical loads — our engineers return a clear kVA recommendation, bill of materials and fixed quote.